Lab
This is the evidence room. Everything here exists so a stranger can check my work instead of taking my word for it. One note on scope: the full paper trail below belongs to CryNet, the flagship build. The other projects carry their evidence in their own case studies.
These sheets are generated, not hand-drawn. The layout tool fails the build if a label overlaps another label, sits on a component, or has a wire crossing it. The first version was hand-written SVG and had wires running straight through labels, which is why the checker exists.
INMP441 on GPIO4/5/6, the C3 Pro Mini, and nothing else that is not load-bearing.
ESP32-S3-DevKitC-1 N16R8 with the ILI9341 on GPIO10–14 and backlight on GPIO4.
SSD1306 OLED and the coin ERM behind a BC547 low-side switch with its 22 Ω stall cap.
The log is the evidence and the wrist is the output. Entries are newest first. Every number here came off a serial console or a measurement script, and the dossier records the commands.
-
2026-11-05/06
Two-cot bench session
993 frames off the air, 993 parsed, 0 bad. Both cot ids survived the flash out of NVS. Node 2 burst: 286/286 fragments in 0.99 s, CRC-32 MATCH. Found a BLE state-publish bug: the wrist read 0 cot(s) until the packet was rebuilt every cycle.
-
2026-11-20
Wearable on the Li-Po pouch
The wrist ran from its pouch and kept working, the first cell-powered run. The haptic buzz went missing while on the pouch; firmware exonerated, sagging 3.3 V rail is the live candidate. Two cots crying at once staged: mask held 0x03 for 15 s.
-
2026-10
Confusion session, 9 takes
Zero false alarms across 308 non-cry windows: speech, music, film, quiet. And the finding that changed the design: a cry at 1 m never crosses the fixed trigger (0/590 records), which is why the adaptive 3× floor exists.
-
2026-10
Demo session
45 bursts, 45/45 complete: no stall, timeout, CRC error or resend. 26 alerts at P(cry) 0.9922–0.9961, 16 refusals at 0.0078–0.2148. Nothing in between: the gap the announcement rule is built on.
-
2026-09
Clipping forensics
Node 2 peaked at 31,801/32,767 and the system named the wrong cot for 42 seconds. Now: any window with a sample ≥ 31,000 is refused outright (CRYNET_CLIP_PEAK).
-
2026-09
Front-end parity campaign
C vs Python on the log-Mel chain: max deviation 7 × 10⁻⁵ on the host; on-chip ≤ 1 LSB, ≤ 1 % of the 5,184 features differing. The model never sees a different world in the field than it trained in.
The full dossier
Twenty-one chapters and two appendices across 684 pages: the system, the research, the signal contract, the model, the firmware for all three units, the radio link, the alert policy, the BLE contract, the cry dashboard, the hardware, the display, the results, the bench, the toolchain, the host tools, the limitations, a replication guide and a glossary. The appendices reproduce the source and the record's own documents, so every claim can be checked against the code. It opens with the honest-status section before any results, because that is the order the numbers should be read in.